
AOD9604 Spray
AOD9604 Spray supplies the modified growth hormone lipolytic domain as a pre-dissolved metered solution, differing from the unmodified 176-191 fragment at a single residue position. Every wholesale lot is ≥99.0% HPLC and LC-MS verified with a batch-specific certificate of analysis. Supplied for Research Use Only (RUO) — not for human consumption or therapeutic use. This liquid compound is synthesized and purified for the sole purpose of scientific investigation. This material is supplied strictly for laboratory research purposes and in-vitro scientific testing in controlled developmental or academic settings. It is not designed, approved, or intended under any circumstances for human consumption, clinical application, medical diagnostics, or direct therapeutic administration.
Commercial Order
MOQ: 10 units minimum per spec
AOD9604 Spray
Access in-depth scientific literature, cellular signaling pathways, and HPLC batch verification for this compound.
Product Specifications
Available Sizes
Wholesale MOQ: 10 Units
Minimum order quantity is 10 units (1 kit).
Contact for Tiered Pricing
Request Pricing
Get current wholesale rates for AOD9604 Spray. Our team responds within 2-4 hours on business days.
All inquiries are strictly confidential. B2B / Institutional orders only.
Clinical Dossier & Technical Digest
Factual reference profile and clinical data specifications.
Metabolic research groups studying adipose tissue are the primary users of AOD9604, and the experimental design is built around demonstrating an absence. A lab working with 3T3-L1 adipocytes or isolated primary adipocytes measures glycerol and free fatty acid release into the medium as the lipolysis readout, then runs full growth hormone in parallel wells while measuring IGF-1 induction alongside. The point of that second arm is the dissociation: the fragment should move lipid metabolism without moving IGF-1, exactly the comparison Heffernan and colleagues published in 2001. Ng and colleagues had characterized the synthetic lipolytic domain in fatty rodent models the year before. A third pairing against the unmodified 176-191 fragment isolates what the single residue substitution changes.
AOD9604 raises one identity question that is easy to get wrong and one structural question that is easy to miss. The identity question concerns its near neighbour: the unmodified 176-191 fragment carries phenylalanine where this compound carries tyrosine, a difference of one hydroxyl group and therefore sixteen mass units. Both are 16 residues long, so length offers no discrimination and only accurate mass analysis separates them; the certificate states which molecule the lot contains, because the two names are used interchangeably in commerce far more often than the chemistry warrants. The structural question is the internal disulfide loop between the two cysteines, confirmed by comparing reduced and non-reduced separations since the open linear form carries an almost identical mass.
Structured Procurement Profile & Technical Reference
- Compound Reference AOD9604 Spray
- CAS Registry 221231-10-3
- Analytical Grade ≥99.0% High-Purity Research Standard
- Authorized Intended Use Strictly for Laboratory Research Purposes Only
- Supply Availability Pre-Dissolved Spray Bulk Kits (10-unit standard)
- Global Authorized Distributor 99 Purity Wholesale
Analytical Quality Assurance Loop
Every lot of AOD9604 Spray undergoes a double-pass chromatography and verification process. We confirm purity by reverse-phase HPLC and identity by exact cation mass using Liquid Chromatography-Mass Spectrometry (LC-MS), alongside metered-solution concentration verification. Finished units are sterile-filtered, nitrogen-purged, and filled into amber glass for long-term molecular stability.
Certificate of Analysis (COA)
Batch-matched HPLC and Mass Spectrometry reports.
AOD9604 Spray Procurement FAQ
Complete institutional procurement guidance, quality verification protocols, and delivery details for bulk wholesale AOD9604 Spray.
What is the verified purity and analytical testing protocol for wholesale AOD9604 Spray?
Every wholesale lot of AOD9604 Spray is verified to ≥99.0% purity by reverse-phase HPLC and confirmed by LC-MS against the expected mass near 1815 Da. Each shipment carries a batch-specific certificate of analysis. The identity check that matters most distinguishes this compound from the unmodified 176-191 fragment, which differs by a single oxygen atom at 1799 Da because its first residue is phenylalanine rather than tyrosine. Disulfide pairing and cysteine oxidation are also screened.
02Is AOD9604 Spray approved for therapeutic use or human consumption?
+
Is AOD9604 Spray approved for therapeutic use or human consumption?
No. AOD9604 Spray is supplied strictly as a Research Use Only (RUO) material for in-vitro laboratory investigation. It is not approved, indicated, or intended for human consumption, medical treatment, diagnostic procedures, veterinary application, or cosmetic use. This RUO material is not a pharmaceutical product and carries no approved indication.
03What is the minimum order quantity for wholesale AOD9604 Spray?
+
What is the minimum order quantity for wholesale AOD9604 Spray?
The minimum order quantity is 10 spray units, which constitutes one standard wholesale kit. 99 Purity Wholesale supplies bulk quantities to research institutions, contract laboratories running adipocyte lipolysis panels, and distribution brands. We do not fulfill retail or single-unit inquiries.
04What physical form is wholesale AOD9604 Spray supplied in?
+
What physical form is wholesale AOD9604 Spray supplied in?
AOD9604 Spray is supplied as a pre-dissolved, sterile-filtered solution in amber glass bottles fitted with a metered atomizer, at 5 mg or 10 mg per unit. Two cysteines form an internal disulfide loop in this 16-residue sequence, so the buffer is selected to keep that bond closed rather than simply to maximise solubility. The amino-terminal tyrosine adds mild photosensitivity, which the amber glass addresses. Headspace is nitrogen-purged before capping, and no reconstitution is required.
05What are the recommended storage conditions and stability limits for AOD9604 Spray?
+
What are the recommended storage conditions and stability limits for AOD9604 Spray?
Store AOD9604 Spray refrigerated at 2°C to 8°C (36°F to 46°F), upright and protected from light, where sealed units remain within specification for up to 24 months. Once the atomizer is first actuated, use the unit within 30 days. Avoid freeze-thaw cycling and keep the material away from reducing agents entirely: the internal disulfide loop defines the fragment conformation, and reduction opens it into a linear peptide with the same residue composition but a different shape. Brief transit excursions to 15°C to 25°C (59°F to 77°F) are tolerated.
06What is the primary molecular target or mechanism of action researched for AOD9604 Spray?
+
What is the primary molecular target or mechanism of action researched for AOD9604 Spray?
AOD9604 is a modified form of the growth hormone lipolytic domain, and the modification is smaller than most descriptions suggest. The unmodified 176-191 fragment begins with phenylalanine; AOD9604 carries tyrosine in that first position instead, which differs by a single hydroxyl group and therefore by one oxygen atom in the molecular formula. Both sequences are 16 residues long. Functionally the compound shares the fragment defining property: it influences adipocyte lipid handling without engaging the growth hormone receptor, so it does not drive hepatic IGF-1 production. Ng and colleagues characterized the synthetic lipolytic domain in fatty rodent models, and Heffernan and colleagues compared it against full growth hormone directly.
07Can I request custom concentrations, vial sizes, or formulations for wholesale AOD9604 Spray?
+
Can I request custom concentrations, vial sizes, or formulations for wholesale AOD9604 Spray?
Yes. Qualified procurement partners can request alternative concentrations, non-standard bottle volumes, unlabeled or private-label presentation, or co-formulation with complementary metabolic research compounds such as H-Frag. Contact our corporate sales desk with your target concentration and unit count to scope the run.
08How is wholesale AOD9604 Spray packaged and shipped to preserve compound integrity?
+
How is wholesale AOD9604 Spray packaged and shipped to preserve compound integrity?
Units ship in light-blocking, vacuum-sealed secondary packaging with temperature-stability buffers that hold the shipment inside the refrigerated range through transit. Amber primary containers and nitrogen-purged headspace protect the internal disulfide loop and the tyrosine at the amino terminus. We ship nationwide across all 50 US states and internationally via express couriers with discrete, border-optimized clearance and full delivery assurance.
Related Research Compounds

5-AMINO-1MQ
Research-grade compound intended strictly for laboratory, analytical, and in-vitro research applications. Not for human consumption, therapeutic use, veterinary use, or diagnostic procedures.

5-Amino-1MQ Spray
5-Amino-1MQ Spray is a pre-dissolved, membrane-permeable quinolinium small molecule supplied as a metered solution for laboratories studying nicotinamide N-methyltransferase (NNMT) inhibition without a reconstitution step. Every wholesale lot is verified by reverse-phase HPLC and LC-MS to ≥99.0% purity with batch-specific certificate of analysis documentation.
Wholesale AOD9604 Spray Available In
We supply licensed institutions and laboratories nationwide. Browse our regional hubs for local delivery timelines and coverage.

