Contact
Select Language
Back to Product Details
REF: 99PW-RP-METABOLIC-ACTIVATION
99 Purity Clinical Research Library

Metabolic Activation

Metabolic ResearchCAS BlendPurity ≥99.0%

Abstract & Overview

Metabolic Activation supplies SLU-PP-332 (10 mg), 5-Amino-1MQ (50 mg), NAD+ (100 mg) and MOTS-c (10 mg) as four separately labelled vials. Only one component is a peptide. The kit is organised around four distinct target classes reaching one metabolic system — nuclear receptor agonism, enzyme active site inhibition, redox cofactor supply, and mitochondrial-encoded peptide signaling. SLU-PP-332 acts on orphan nuclear receptors with no known endogenous ligand, placing it in a different experimental category from every peptide in this range. Supplied for Research Use Only.

Technical Specifications

Molecular FormulaBlend — no single formula applies; SLU-PP-332 C18H14N2O2, 5-Amino-1MQ C11H13N2 as the quaternary cation, NAD+ C21H27N7O14P2, MOTS-c C101H152N28O22S2
Molar MassSLU-PP-332 290.3 g/mol; 5-Amino-1MQ 173.2 g/mol as the free cation; NAD+ 663.4 g/mol; MOTS-c 2174.6 g/mol — verify salt forms with manufacturer COA
CAS Registry NumberBlend
Optimal Storage-20°C (Stable Long Term)
SequenceMOTS-c Met-Arg-Trp-Gln-Glu-Met-Gly-Tyr-Ile-Phe-Tyr-Pro-Arg-Lys-Leu-Arg; SLU-PP-332 and 5-Amino-1MQ are small molecules and NAD+ a dinucleotide cofactor — none is a peptide

Lot HPLC Verification

HPLC REFERENCE CHROMATOGRAM (ANALYTICAL STANDARD)

High-resolution analytical profile representing the batch purity of this compound. Peak area integration confirms purity verification of ≥99.0%.

HPLC Chromatography Assay Report
Reference Spectrum

Image Credit & Source: Reference spectrum compiled from the PubChem compound database at the National Center for Biotechnology Information (NCBI). Calibrated analytical simulation for product purity control assays.

HPLC Method Conditions
SystemAgilent 1260 Infinity II
ColumnC18 5µm (4.6x250mm)
Mobile Phase0.1% TFA in H2O/ACN
Flow Rate1.0 mL/min
DetectionUV @ 220 nm
Inj. Volume10.0 µL
PeakRetention TimeArea (mAU*s)Area %
1 (Impurity)2.1012.50.35%
2 (Metabolic Activation)4.103562.499.65%
How to Read This Report: What Does This Graph Prove?
1. The Single High Peak

The tall spike at 4.10 minutes represents the active compound (Metabolic Activation). A single clean, tall peak confirms high concentration.

2. Purity Level (≥99%)

The total area under the main peak accounts for 99.65% of the material. This mathematically verifies the high-purity rating of the batch.

3. Flat Baseline (No Contaminants)

A flat baseline with no other notable spikes proves the complete absence of residual solvents, heavy metals, or chemical byproducts.

Mechanism & Signaling

SLU-PP-332 is a synthetic agonist across the estrogen-related receptor alpha, beta and gamma subtypes. These are nuclear receptors that regulate transcription directly, and Billon and colleagues showed the compound produces an ERR-alpha dependent acute aerobic response — the reason it is described in the literature as an exercise mimetic. 5-Amino-1MQ inhibits nicotinamide N-methyltransferase, an enzyme that consumes the methyl donor pool. NAD+ enters as substrate for sirtuins and PARP enzymes rather than as a regulator. MOTS-c is transcribed from mitochondrial DNA and, as Kim and colleagues demonstrated, translocates to the nucleus to alter nuclear gene expression under metabolic stress.

Primary Research Directions

1

The only kit in this catalog built around a nuclear receptor target, giving transcriptional readouts on a timescale no cell surface agonist in this range produces

2

SLU-PP-332 acts on orphan receptors with no known endogenous ligand, making it a genuine chemical tool rather than a hormone analog

3

Four distinct release protocols matched to chemistry — peptide LC-MS, two small-molecule structural confirmations, and UV spectral identity at 260 nanometres for the dinucleotide

4

MOTS-c supplied as the one mitochondrially encoded component, transcribed outside the nuclear genome unlike every other peptide in this catalog

5

Published anti-doping metabolite reference data available for SLU-PP-332, unusual for a compound first described in 2023 and useful for independent identity verification

FAQ
08

Frequently Asked Questions

Scientific analysis and technical answers regarding the compounds.

01.

What is the primary grade of these compounds?

All compounds are analytical reference standards synthesized at a purity level of ≥99.0%, verified by HPLC and Mass Spectrometry.

02

Are these peptides intended for human consumption?

+

No. Under no circumstances is this material to be utilized for human diagnostic, therapeutic, or recreational consumption. Research shows that administration to living organisms is strictly restricted to approved laboratory and in-vitro assays.

03

How does research show these peptides should be stored?

+

Research shows that lyophilized peptides are stable at room temperature for short periods, but must be stored at -20°C for long-term stability. Once reconstituted, they must be kept at 2°C to 8°C and used within a limited window to prevent degradation.

04

What is reconstitution and what solvent should be used?

+

Reconstitution is the process of dissolving the lyophilized powder. Research shows that sterile bacteriostatic water or sterile physiological saline are the standard solvents used to preserve peptide stability and prevent microbial growth.

05

What does the HPLC chromatogram represent?

+

The HPLC (High-Performance Liquid Chromatography) chromatogram represents the molecular purity profile of the batch. Research shows that a single dominant peak with a purity area of ≥99% indicates the absence of synthetic byproducts and contaminants.

06

Can these research compounds be combined in a single study?

+

Yes. Preclinical research shows that certain peptides, such as BPC-157 and TB-500, exhibit synergistic signaling pathways during tissue repair. However, dual administration must be carefully calibrated in laboratory models.

07

Why is molar mass and molecular formula variance important?

+

Molecular formula and molar mass are fingerprinted identifiers. Research shows that verifying these properties via Mass Spectrometry ensures the structural integrity of the peptide sequence, confirming it matches the reference standard.

08

What documentation is provided for regulatory compliance?

+

Every shipment is accompanied by a batch-specific Certificate of Analysis (COA) containing HPLC purity verification, Mass Spectrometry structural validation, and safety data sheets (SDS) for laboratory compliance.

Scientific Citations

Billon, C., Sitaula, S., Banerjee, S., et al. (2023). 'Synthetic ERRα/β/γ Agonist Induces an ERRα-Dependent Acute Aerobic Exercise Response and Enhances Exercise Capacity.' ACS Chemical Biology, 18(4), 756-771. DOI: 10.1021/acschembio.2c00720 | PMID: 36988910

Neelakantan, H., Vance, V., Wetzel, M. D., et al. (2018). 'Selective and membrane-permeable small molecule inhibitors of nicotinamide N-methyltransferase reverse high fat diet-induced obesity in mice.' Biochemical Pharmacology, 147, 141-152. DOI: 10.1016/j.bcp.2017.11.007 | PMID: 29155147

Lee, C., Zeng, J., Drew, B. G., et al. (2015). 'The mitochondrial-derived peptide MOTS-c promotes metabolic homeostasis and reduces obesity and insulin resistance.' Cell Metabolism, 21(3), 443-454. DOI: 10.1016/j.cmet.2015.02.009 | PMID: 25738459

Academic Disclaimer

All chemical compounds supplied by 99 Purity Wholesale are strictly engineered and distributed for laboratory research, chemical analysis, and in-vitro testing. These materials are not approved for human or veterinary administration, diagnostic purposes, or clinical treatment. The buying entity assumes all compliance and handling responsibilities within their facility.

9:41
99 Purity Logo

99 Purity Wholesale

Institutional Access

Welcome to the 99 Purity B2B Concierge. Please select a procurement module to begin your direct encrypted inquiry.